Non-Tariff Measure

NTM classification
B14: Authorization requirements for importing certain products 
Date when the measure came into force
19 May 2011 
Publication where the measure is specified
Government Gazette No. 33763, 19 November 2010 
Regulation where the measure is specified
Amendment Of Compulsory Specification For The Safety Of Flexible Cords For Electrical Appliances (VC 8006) 
Country/Region applying the measure
South Africa 
The rationale of the measure
This specification covers the safety requirements for insulated single core flexible cords rated at a minimum of 500 V ac and multiple core flexible electric cords rated at a minimum of 300/500 V ac. These flexible cords are
intended to connect single or 3 - phase appliances, luminaires and light industrial equipment to a low voltage mains supply conforming to the standard applicable in the Republic of South Africa Le. 230 V +- 10% single phase ac., or 400 V +- 10% three phase ac. 
Description of the measure
3.3 The applicant shall ensure that every type of flexible cord has been approved by the NRCS before offering it for sale, in accordance with the requirements of Annex A.

A.1 APPLICATION FOR APPROVAL
An application for approval of each type of flexible cord intended for sale shall include:
A.1.1 Details of the type of flexible cord for which approval is sought and the standard/s to which it is claimed to conform;
A.1.2 Details of the manufacturing plan/s in which the flexible cord is produced;
A.1.3 For new applications, proof of conformity, with all the requirements of this compulsory specification, issued less than 36 months before the date of submission to the NRCS;
A.1.4 On expiry of the approval, an application for an extension may be granted, provided that all the conditions of the previous approval were met. In this case, proof of compliance, with all the requirements of the relevant compulsory specification, issued less than 60 months before the date of submission to the NRCS, shall be
required;
A.1.5 Identification markings and other information appearing on the product; and
A.1.6 Any reasonable additional information as may be requested by the NRCS 
Reference of the measure
Regulations 3.3 and Annex A.1 
Measure also domestic
Yes 

Products affected by the measure.

Code Product Partial coverage Partial coverage indication Date in Date out
8544 Insulated (including enamelled or anodised) wire, cable (including coaxial cable) and other insulated electric conductors, whether or not fitted with connectors; optical fibre cables, made up of individually sheathed fibres, whether or not assembled with Yes Flexible cord: Length of one or more flexible cores of cross-sectional area not more than 4 mm 2 , with or without protective covering for domestic and light duty applications    
Description
Flexible cord: Length of one or more flexible cores of cross-sectional area not more than 4 mm 2 , with or without protective covering for domestic and light duty applications 

Countries/Regions affected by the measure.

Inclusion/Exclusion Country Date in Date out
Inclusion Entire world    
Description
All countries