Non-Tariff Measure
- NTM classification
- B7: Product quality, safety or performance requirements
- Date when the measure came into force
- 20 February 1998
- Publication where the measure is specified
- Supplement to the Republic of Zambia Government Gazette dated 20/02/1998. statutory Instrument No 22 of 1998,the weights and Measures Act
- Regulation where the measure is specified
- The weights and Measures (assize) regulations, 1998
- Country/Region applying the measure
- Zambia
- Coded list of objectives
- X: For purposes n.e.s.
- Description of the measure
- 29. (1) In a spring balance—
(a) The chart shall—
(i) be clearly and indelibly marked " TRADE SPRING BALANCE " or " FOR TRADE USE ";
(ii) bear a statement of the weight "e" value; and
(iii) be made of white enamel, polished brass, or an approved material so protected that the graduation and other markings are clearly visible;
(b) the graduation on the chart shall not—
(i) exceed 0.8mm in width; and
(ii) be less than 3mm apart, measured from the centre to centre, whether or not they are on opposite sides of a dividing line;
(c) where a temperature compensating device or iso-elastic spring is incorporated, it shall be capable of compensating temperature variations of 10 degrees Celsius in balance and at load;
(d) any ball-bearing unit shall be protected against dust and dirt;
(e) the extremity of the indicating pointer shall not—
(i) exceed in width or thickness the width of any graduation; and
(ii) be more than 2min from the chart;
(f) a suitable balancing device capable of adjustment only by use of a mechanical appliance shall be provided; and
(g) be back balanced with a bag, sack, pan or other means of loading, which fact shall be clearly stated on the chart.
(3) The range of balance shall not exceed one percent of the capacity of the spring balance.
(4) A spring balance shall be tested—
(a) for accuracy of weighing at as many graduations as possible in increasing and decreasing loads;
(b) for endurance at a load equal to the capacity of the balance for a period not exceeding 24 hours and after expiration of a further four hours testing for accuracy.
(5) Subject to the provisions of regulation 15, the maximum permissible error shall be as specific in Tables 3, 5 and 6 of the First Schedule as applicable.
(6) The stamp of assize shall be stamped upon a lead plug inserted in the chart, or in a prominent position on the instrument - Reference of the measure
- Part IV Section 29 a (iii)-3
- Measure also domestic
- Yes
Products affected by the measure.
Code | Product | Partial coverage | Partial coverage indication | Date in | Date out |
---|
8423.8 | - Other weighing machinery : | Yes | Spring Balance | | |