US ISO 11119-2: 2012, Gas cylinders — Refillable composite gas cylinders and tubes — Design, construction and testing — Part 2: Fully wrapped fibre reinforced composite gas cylinders and tubes up to 450 l with load-sharing metal liners

This Uganda Standard specifies requirements for composite gas cylinders and tubes between 0.5 l and 450 l water capacity, for the storage and conveyance of compressed or liquefied gases. This standard applies to type 3 fully wrapped cylinders or tubes with a load-sharing metal liner and composite reinforcement on both the cylindrical portion and the dome ends. This standard is limited to cylinders and tubes with composite reinforcement of carbon fibre, aramid fibre or glass fibre (or a mixture thereof) within a matrix.

Source of regulation
The Uganda National Bureau of standards 
Publication of regulation
UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 
Date of implementation
21 April 2015 
Regulation file