Regulations

Page 127 of 140, showing 20 records out of 2786 total, starting on record 2521, ending on 2540

Title Description Implementation date Source Publication Created
US ISO 24011:2009, Resilient floor coverings — Specification for plain and decorative linoleum This Uganda Standard specifies the characteristics of plain and decorative linoleum, supplied as either tiles or rolls. To encourage the consumer to make an informed choice, this standard includes a classification system based on the intensity of use, which shows where resilient floor coverings provide satisfactory service. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 17 September 2016
US EAS 489:2008, Concrete poles for telephone, power and lighting purposes — Specification This Uganda Standard specifies the characteristics of pre-cast reinforced, partially pre-stressed and pre-stressed concrete poles. Possible uses for the poles include electrical reticulation and distribution, railway traction, telephone line support, street lighting standards and high mast lighting structures. 2017-02-03 The Uganda National Bureau of standards The Uganda Gazette, Vol. CX No. 7 22 March 2017
US ISO 7900:2006, Steel wire and wire products for fences — Zinc- and zinc-alloy coated steel barbed wire This Uganda Standard specifies the characteristics of zinc- and zinc-alloy-coated steel barbed wire, with conventional and reverse twist consisting of two stranded line wires, around which the barbs are tightly wound, a twist being imparted between the barbs to restrict their movement. The barbed-wire entanglement has a single line wire, around which the barbs are wound. 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 02 November 2016
US ISO 7900:2006, Steel wire and wire products for fences — Zinc- and zinc-alloy coated steel barbed wire This Uganda Standard specifies the characteristics of zinc- and zinc-alloy-coated steel barbed wire, with conventional and reverse twist consisting of two stranded line wires, around which the barbs are tightly wound, a twist being imparted between the barbs to restrict their movement. The barbed-wire entanglement has a single line wire, around which the barbs are wound. (This Uganda Standard cancels and replaces US 193:2001, Specification for steel wires and wire products used for fencing, which has been technically revised and republished). 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 12 April 2017
US ISO 6361-5:2011, Wrought aluminium and aluminium alloys — Sheets, strips and plates — Part 5: Chemical composition This Uganda Standard specifies the chemical composition of wrought aluminium and aluminium alloys. 2016-08-12 The Uganda National Bureau of standards The Uganda Gazette Vol. CVIII No. 57 03 September 2016
US ISO 6362-7:2016, Wrought aluminium and aluminium alloys — Extruded rods/bars, tubes and profiles — Part 7: Chemical composition This Uganda Standard specifies the chemical composition of wrought aluminium and aluminium alloys. 2016-08-12 The Uganda National Bureau of standards The Uganda Gazette Vol. CVIII No. 57 03 September 2016
US 945-1:2012, Pre-insulated flexible pipe systems — Part.1: Classification, general requirements and methods of test This Uganda Standard specifies the classification, general requirements and methods of test for flexible, pre-insulated, directly buried district heating pipe systems. Depending on the pipe assembly, this standard can be used for maximum operating temperatures of 95 °C to 140 °C and operating pressures of 6 bar to 25 bar. The pipe systems are designed for a lifetime of 30 years. For pipe systems with plastic service pipes, the respective temperature profiles are defined in US 945-2. 2013-04-12 The Uganda National Bureau of standards Uganda Gazette Vol. CV No. 17 of 12th April 2013 10 May 2017
US IEC 60502-1:2009, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) - Part 1: Cables for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) This Uganda Standard specifies the construction, dimensions and test requirements of power cables with extruded solid insulation for rated voltages of 1 kV (Um = 1,2 kV) and 3 kV (Um = 3,6 kV) for fixed installations such as distribution networks or industrial installations. (This Uganda Standard cancels and replaces, US EAS 506-1:2008, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV) — Part 1: Cables for rated voltages of 1 kV (Um = 1.2 kV) and 3 kV (Um = 3.6 kV), which has been republished). 2015-08-07 The Uganda National Bureau of standards 24 August 2016
US IEC 60502-2:2014, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) – Part 2: Cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV) This Uganda Standard specifies the construction, dimensions and test requirements of power cables with extruded solid insulation from 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. (This Uganda Standard cancels and replaces, US EAS 506-2:2008, Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1.2 kV) up to 30 kV (Um = 36 kV) — Part 2: Cables for rated voltages from 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV), which has been republished) 2015-08-07 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVIII No. 43 of 7 August 2015 24 August 2016
US ISO 7225:2005, Gas cylinders — Precautionary labels This Uganda Standard specifies the design, content (that is, hazard symbols and text) and application of precautionary labels intended for use on individual gas cylinders containing single gases or gas mixtures. Labels for cylinders of bundles and labels for bundles are not covered by this standard.. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 04 October 2016
US ISO 209:2007, Aluminium and aluminium alloys — Chemical composition This Uganda Standard specifies the designations indicating the chemical composition of aluminium and aluminium alloys. 2016-08-12 The Uganda National Bureau of standards The Uganda Gazette Vol. CVIII No. 57 03 September 2016
US ISO 1825:2010, Rubber hoses and hose assemblies for aircraft ground fuelling and defuelling — Specification This Uganda Standard specifies the dimensions and construction of, and requirements for, four types of hose and hose assembly for use in all operations associated with the ground fuelling and defuelling of aircraft. All four types are designed for use with petroleum fuels having an aromatic-hydrocarbon content not exceeding 30 % by volume; operation within the temperature range of −30 °C to +65 °C and such that they will be undamaged by climatic conditions of −40 °C to +70 °C when stored in static conditions; andoperation at up to 2,0 MPa (20 bar) maximum working pressure, including surges of pressure which the hose can be subjected to in service. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 17 September 2016
US EAS 134:2013, Cold rolled steel sections — Specification (2nd Edition) This Uganda Standard specifies the dimensions and sectional properties of cold rolled steel sections of thickness up to 8 mm for use in structural applications. 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 02 November 2016
US EAS 134:2013, Cold rolled steel sections — Specification (2nd Edition) This Uganda Standard specifies the dimensions and sectional properties of cold rolled steel sections of thickness up to 8 mm for use in structural applications. (This Uganda Standard cancels and replaces US EAS 134:1999, Cold rolled steel sections – Specification, which has been technically revised). 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 12 April 2017
US ISO 5183-2:2000, Resistance welding equipment — Electrode adaptors, male taper 1:10 — Part 2: Parallel shank fixing for end-thrust electrodes This Uganda Standard specifies the dimensions and tolerances of resistance spot welding electrode adaptors where the fixing element for the cap is a male taper of 1:10 and a parallel shaft is used to fix the adaptor to the electrode holder in accordance with US ISO 8430-3. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 5183-1:1998, Resistance welding equipment — Electrode adaptors, male taper 1:10 — Part 1: Conical fixing, taper 1:10 This Uganda Standard specifies the dimensions and tolerances of resistance spot welding electrode adaptors where the fixing element for the cap is a male taper of 1:10 and for which the electrode taper fits in conformance with US ISO 1089. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 8430-2:1988, Resistance spot welding — Electrode holders — Part 2: Morse taper fixing This Uganda Standard specifies the dimensions and tolerances of resistance spot welding electrode holders (type 9) without offset and with a facility for cable clamping, and where a male Morse taper is used to fix the holder directly to the welding cylinder in multiple spot welding equipment. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 8430-1:1988, Resistance spot welding — Electrode holders — Part 1: Taper fixing 1:10 This Uganda Standard specifies the dimensions and tolerances of resistance spot welding electrode holders (type AI without offset and with the facility for cable clamping, and where a male taper 1:10 is used to fix the holder directly to the welding cylinder in multiple spot welding equipment. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 8430-3:1988, Resistance spot welding — Electrode holders — Part 3: Parallel shank fixing for end thrust This Uganda Standard specifies the dimensions and tolerances of resistance spot welding electrode holders (type C) without offset and with a facility for cable clamping, and where a clamp is used to fix the holder directly to the welding cylinder in multiple spot welding equipment. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 6699:1990, Cycles — Stern and handlebar bend — Assembly dimensions This Uganda Standard specifies the dimensions and tolerances to ensure secure assembly between the stem and the handlebar bend of a bicycle. lt applies to bicycles intended for use on public roads, and on which the saddle can be adjusted to provide a saddle height of 635 mm or more. lt does not apply to specialized types of bicycle such as tradesmen’s delivery bicycles, tandems, toy bicycles and bicycles designed and equipped for use in sanctioned competitive events. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
1 2 3...125 126 127 128 129...138 139 140