US ISO 7240-22:2007, Fire detection and alarm systems — Part 22: Smoke-detection equipment for ducts This Uganda Standard specifies requirements, test methods and performance criteria for smoke-detection equipment for ducts (s.d.e.d.) for use in fire-detection and fire alarm systems installed in buildings (see US ISO 7240-1). The s.d.e.d. samples the air from a duct and detects smoke in the sample. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-23:2013, Fire detection and alarm systems — Part 23: Visual alarm devices This Uganda Standard specifies the requirements, test methods and performance criteria for visual alarm devices in a fixed installation intended to signal a visual warning of a fire between a fire detection and alarm system and occupants in and around buildings. This standard specifies visual alarm devices for three types of application environment. It is only applicable to pulsing or flashing visual alarm devices, for example xenon beacons or rotating beacons. It is not applicable to devices giving continuous light output. This standard is not intended to cover visual indicators, for example, on detectors or on the control and indicating equipment. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-24:2010, Fire detection and alarm systems — Part 24: Sound-system loudspeakers This Uganda Standard specifies requirements, test methods and performance criteria for loudspeakers intended to broadcast a warning of fire between a fire detection and alarm system and the occupants of a building (see US ISO 7240-1). This standard specifies loudspeakers for two types of application environment: type A, generally for indoor use, and type B, generally for outdoor use. This standard does not cover loudspeakers for special applications, for example loudspeakers for use in hazardous applications, if such applications require additional or other requirements or tests other than those given in this standard. This standard is not intended to cover addressable loudspeakers or loudspeakers with active components. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-25:2010, Fire detection and alarm systems — Part 25: Components using radio transmission paths This Uganda Standard specifies requirements, test methods and performance criteria for components used in fire detection and alarm systems, installed in and around buildings, which use radio-frequency (r.f.) transmission paths. It specifies requirements for the assessment of conformance of the components to the requirements of this standard. Where components work together and this requires knowledge of the system design, this standard also specifies requirements for the system. When the fire detection and alarm system uses wired and r.f. transmission paths, the relevant parts of US ISO 7240 apply together with this part of US ISO 7240. Requirements relevant to wire transmission paths are superseded or modified by those included in this standard. This standard does not restrict the intended use of radio spectrum, e.g. frequency, power output of devices;the allowed maximum number of the components using r.f. transmission paths within the fire detection and alarm system or one wire transmission path and/or r.f. transmission path; andthe allowed maximum number of the components affected by loss of one wire transmission path and/or r.f. transmission path. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-27:2009, Fire detection and alarm systems — Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat sensor This Uganda Standard specifies requirements, test methods and performance criteria for multi-sensor point-type fire detectors that incorporate an optical or ionization smoke sensor, an electro-chemical cell for sensing carbon monoxide (CO) and, optionally, one or more heat sensors, for use in fire detection and alarm systems installed in buildings (see US ISO 7240-1). For the testing of other types of fire detectors using smoke, CO and, optionally, heat sensors working on different principles, this standard can be used only for guidance. Fire detectors using smoke, CO and, optionally, heat sensors which have special characteristics and which have been developed for specific risks are not covered by this standard. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-28:2009, Fire detection and alarm systems — Part 28: Fire protection control equipment This Uganda Standard specifies requirements, methods of test and performance criteria for fire protection control equipment (f.p.c.e.) (see ISO 7240-1) connected to automatic fire protection equipment (a.f.p.e.) (see ISO 7240-1) installed in buildings. The f.p.c.e. receives signals from control and indicating equipment (see ISO 7240-1), sends control signals to, and indicates the condition of, the a.f.p.e. The control signals are used to initiate automatic fire protection equipment, such as pumps associated with fire suppression systems, control doors, dampers, fans and the like. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7240-2:2003, Fire detection and alarm systems — Part 2: Control and indicating equipment This Uganda Standard specifies requirements, test methods and performance criteria for control and indicating equipment (c.i.e.) for use in fire detection and fire alarm systems installed in buildings. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-3:2010, Fire detection and alarm systems — Part 3: Audible alarm devices This Uganda Standard specifies the requirements, test methods and performance criteria for audible alarm devices intended to signal an audible warning of fire between a detection and alarm system and the occupants of a building. It is intended to cover only those devices which derive their operating power by means of a physical electrical connection to an external source such as a fire alarm system. This part of US ISO 7240 is also intended to cover audible alarm devices capable of giving voice messages by the application of specific requirements, tests and performance criteria. This standard specifies fire alarm audible alarm devices for two types of application environment, type A for indoor use and type B for outdoor use. This part of US ISO 7240 is not intended to cover: loudspeaker-type devices primarily intended for emitting emergency voice messages that are generated from an external audio source; and supervisory audible alarm devices, e.g. within the control and indicating equipment. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-4:2003, Fire detection and alarm systems — Part 4: Power supply equipment This Uganda Standard specifies requirements, test methods and performance criteria for power supply equipment (p.s.e.) for use in fire detection and alarm systems installed in buildings. It is not necessarily applicable to power supply equipment with special characteristics, developed for particular applications, which could require further tests. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-5:2012, Fire detection and alarm systems — Part 5: Point-type heat detectors This Uganda Standard specifies requirements, test methods and performance criteria for point-type heat detectors for use in fire detection and fire alarm systems for buildings (see US ISO 7240-1). For other types of heat detector or for detectors intended for use in other environments, this standard should only be used for guidance. This standard is not applicable to heat detectors with special characteristics and developed for specific risks. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-6:2011, Fire detection and alarm systems — Part 6: Carbon monoxide fire detectors using electro-chemical cells This Uganda Standard specifies requirements, test methods and performance criteria for point fire detectors using electro-chemical cells that operate using carbon-monoxide detection principles for use in fire detection and alarm systems installed in buildings (see US ISO 7240-1). For the testing of other types of CO fire detectors working on different principles, this part of US ISO 7240 can be used only for guidance. Fire detectors with special characteristics and developed for specific risks are not covered by this standard. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-7:2011, Fire detection and alarm systems — Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization This Uganda Standard specifies requirements, test methods and performance criteria for point-type smoke detectors that operate using scattered light, transmitted light or ionization, for use in fire detection and alarm systems installed in buildings (see US ISO 7240-1). This standard also covers point smoke detectors that incorporate more than one smoke sensor operating on these principles. Additional requirements and test methods for such detectors are given in Annex N. For the testing of other types of smoke detectors, or smoke detectors working on different principles, this standard can be used only for guidance. Smoke detectors with special characteristics, developed for specific risks, are not covered 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7240-8:2007, Fire detection and alarm systems — Part 8: Carbon monoxide fire detectors using an electro-chemical cell in combination with a heat sensor This Uganda Standard specifies requirements, test methods and performance criteria for point multi-sensor fire detectors that incorporate an electrochemical cell for sensing carbon monoxide (CO) in combination with one or more heat sensors, for use in fire detection and alarm systems installed in buildings (see US ISO 7240-1). For the testing of other types of CO multi-sensor fire detectors, or CO and heat multi-sensor fire detectors working on different principles, this standard can be used for guidance. CO and heat multi-sensor fire detectors with special characteristics and developed for specific risks are not covered by this standard. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 30 September 2016
US ISO 7291:2010, Gas welding equipment — Pressure regulators for manifold systems used in welding, cutting and allied processes up to 30 MPa (300 bar) This Uganda Standard specifies requirements and test methods for pressure regulators in manifold systems used in welding, cutting, and allied processes for: compressed gases up to 30 MPa (300 bar);dissolved acetylene;liquefied petroleum gases (LPG);methylacetylene-propadiene-mixtures (MPS);carbon dioxide (CO2).It is not applicable to pressure regulators fitted directly to the gas cylinders, as defined in US ISO 2503. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 764:2002, Horology — Magnetic resistant watches This Uganda Standard specifies the minimum requirements and test methods for magnetic resistant watches. It is based on the simulation of an accidental exposure of a watch to a direct current magnetic field of 4 800 A/m. Annex A deals with watches designated as magnetic resistant with an additional indication of intensity of a magnetic field exceeding 4 800 A/m. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 03 October 2016
US ISO 7866:2012, Gas cylinders — Refillable seamless aluminium alloy gas cylinders — Design, construction and testing This Uganda Standard specifies minimum requirements for the material, design, construction and workmanship, manufacturing processes and tests at time of manufacture of refillable seamless aluminium alloy gas cylinders of water capacities up to and including 150 litres for compressed, liquefied and dissolved gases for worldwide use (normally up to +65 °C). 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 14 September 2016
US ISO 7900:2006, Steel wire and wire products for fences — Zinc- and zinc-alloy coated steel barbed wire This Uganda Standard specifies the characteristics of zinc- and zinc-alloy-coated steel barbed wire, with conventional and reverse twist consisting of two stranded line wires, around which the barbs are tightly wound, a twist being imparted between the barbs to restrict their movement. The barbed-wire entanglement has a single line wire, around which the barbs are wound. 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 02 November 2016
US ISO 7900:2006, Steel wire and wire products for fences — Zinc- and zinc-alloy coated steel barbed wire This Uganda Standard specifies the characteristics of zinc- and zinc-alloy-coated steel barbed wire, with conventional and reverse twist consisting of two stranded line wires, around which the barbs are tightly wound, a twist being imparted between the barbs to restrict their movement. The barbed-wire entanglement has a single line wire, around which the barbs are wound. (This Uganda Standard cancels and replaces US 193:2001, Specification for steel wires and wire products used for fencing, which has been technically revised and republished). 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 12 April 2017
US ISO 7931: 1985, Insulation taps and bushes for resistance welding equipment This Uganda Standard specifies dimensions and requirements for insulated taps and bushes in the secondary circuit for resistance welding equipment, especially for use in back-ups according to ISO 5827. 2015-04-21 The Uganda National Bureau of standards UGANDA GAZETTE Vol. CVIII No. 20 of 21 April 2015 28 September 2016
US ISO 7989-2:2007, Steel wire and wire products — Nonferrous metallic coatings on steel wire — Part 2: Zinc or zinc-alloy coating This Uganda Standard specifies the requirements for the coating mass per unit area, for other properties and also for testing of zinc or zinc-alloy coatings on steel wire and steel wire products, of circular or other section. 2014-01-27 The Uganda National Bureau of standards THE UGANDA GAZETTE Vol. CVII No. 5 of JANUARY 2014 02 November 2016